OBJECTIVES: To evaluate the utility of dielectric blood coagulometry for early sepsis-induced disseminated intravascular coagulation diagnosis.

DESIGN: Single-center, prospective observational study.

SETTING: Patients with sepsis or septic shock at the Tokyo Medical and Dental University Hospital of Medicine between September 2019 and September 2020.

PATIENTS: The patients were divided into three groups according to the timing of disseminated intravascular coagulation diagnosis based on the Disseminated Intravascular Coagulation score by the Japanese Association for Acute Medicine: 1) no disseminated intravascular coagulation group, 2) late-diagnosed disseminated intravascular coagulation group: not diagnosed with disseminated intravascular coagulation on day 1 but diagnosed within 48 hours after admission, and 3) disseminated intravascular coagulation group: diagnosed with disseminated intravascular coagulation on day 1. The study evaluated 80 patients (no disseminated intravascular coagulation, 31 [38.8%]; late-diagnosed disseminated intravascular coagulation, 34 (42.5%); disseminated intravascular coagulation, 15 [18.8%]).

MEASUREMENTS AND MAIN RESULTS: We compared the clinical severity scores and mortality of the groups and assessed the correlation between the dielectric blood coagulometry-derived coagulation marker, thrombin levels, and Disseminated Intravascular Coagulation score using Spearman rank correlation. The mortality rate was 0% (0/31) in the no disseminated intravascular coagulation group, 35.3% (12/34) in the late-diagnosed disseminated intravascular coagulation group, and 33.3% (5/15) in the disseminated intravascular coagulation group. Although the Disseminated Intravascular Coagulation score on day 1 did not reflect disseminated intravascular coagulation in approximately 70% of patients who developed disseminated intravascular coagulation by day 2, dielectric clot strength measured by dielectric blood coagulometry on day 1 strongly correlated with disseminated intravascular coagulation development by day 2 (Spearman ρ = 0.824; p < 0.05) and with thrombin level on day 1 (Spearman ρ = 0.844; p < 0.05).

CONCLUSIONS: Dielectric blood coagulometry can be used to detect early-phase disseminated intravascular coagulation in patients with sepsis and is strongly correlated with thrombin levels. Larger studies are needed to verify our results for developing clinical applications.