Evaluation of electrocardiographic ventricular repolarization variables in patients with newly diagnosed COVID-19

Link to article at PubMed

J Electrocardiol. 2020 Jul 21;62:5-9. doi: 10.1016/j.jelectrocard.2020.07.005. Online ahead of print.

ABSTRACT

INTRODUCTION: Coronavirus disease 2019 (COVID-19) is a newly recognized infectious disease that has spread rapidly. COVID-19 has been associated with a number of cardiovascular complications, including arrhythmias. The mechanism of ventricular arrhythmias in patients with COVID-19 is uncertain. The aim of the present study was to evaluate the ventricular repolarization by using the Tp-e interval, QT dispersion, Tp-e/QT ratio, and Tp-e/QTc ratio as candidate markers of ventricular arrhythmias in patients with newly diagnosed COVID-19. In addition, the relationship between the repolarization parameters and the CRP (C-reactive protein) was investigated.

METHODS: 75 newly diagnosed COVID-19 patients, 75 age and sex matched healthy subjects were included in the study between 20th March 2020 and 10th April 2020. The risk of ventricular arrhythmias was evaluated by calculating the electrocardiographic Tp-e and QT interval, Tp-e dispersion, corrected QT(QTc), QT dispersion (QTd), corrected QTd, Tp-e/QT and Tp-e/QTc ratios. CRP values were also measured in patients with newly diagnosed COVID-19.

RESULTS: Tp-e interval (80.7 ± 4.6 vs. 70.9 ± 4.8; p < .001), Tp-e / QT ratio (0.21 ± 0.01 vs. 0.19 ± 0.01; p < .001) and Tp-e/QTc ratio (0.19 ± 0.01 vs.0.17 ± 0.01; p < .001) were significantly higher in patients with newly diagnosed COVID-19 than the control group. There was a significant positive correlation between Tp-e interval, Tp-e/QTc ratio and CRP in patients with newly diagnosed COVID-19 (rs = 0.332, p = .005, rs = 0.397, p < .001 consecutively). During their treatment with hydroxychloroquine (HCQ), azithromycin and favipiravir, ventricular tachycardia episodes were observed in in two COVID-19 patients during their hospitalization in the intensive care unit.

CONCLUSION: Our study showed for the first time in literature that the Tp-e interval, Tp-e/QT ratio, and Tp-e/QTc ratio, which are evaluated electrocardiographically in patients with newly diagnosed COVID-19, were prolonged compared with normal healthy individuals. A positive correlation was determined between repolarization parameters and CRP. We believe that pre-treatment evaluation of repolarization parameters in newly diagnosed COVID-19 would be beneficial for predicting ventricular arrhythmia risk.

PMID:32731139 | DOI:10.1016/j.jelectrocard.2020.07.005

Leave a Reply

Your email address will not be published. Required fields are marked *