Resuscitation of the patient with suspected/confirmed COVID-19 when wearing personal protective equipment: A randomized multicenter crossover simulation trial.

Link to article at PubMed

Related Articles

Resuscitation of the patient with suspected/confirmed COVID-19 when wearing personal protective equipment: A randomized multicenter crossover simulation trial.

Cardiol J. 2020 May 18;:

Authors: Malysz M, Dabrowski M, Böttiger BW, Smereka J, Kulak K, Szarpak A, Jaguszewski M, Filipiak KJ, Ladny JR, Ruetzler K, Szarpak L

Abstract
BACKGROUND: The aim of the study was to evaluate various methods of chest compressions in patients with suspected/confirmed SARS-CoV-2 infection conducted by medical students wearing full personal protective equipment (PPE) for aerosol generating procedures (AGP).
METHODS: This was prospective, randomized, multicenter, single-blinded, crossover simulation trial. Thirty-five medical students after an advanced cardiovascular life support course, which included performing 2-min continuous chest compression scenarios using 3 methods: (A) manual chest compression (CC), (B) compression with CPRMeter, (C) compression with LifeLine ARM device. During resuscitation they are wearing full personal protective equipment for aerosol generating procedures.
RESULTS: The median chest compression depth using manual CC, CPRMeter and LifeLine ARM varied and amounted to 40 (38-45) vs. 45 (40-50) vs. 51 (50-52) mm, respectively (p = 0.002). The median chest compression rate was 109 (IQR; 102-131) compressions per minute (CPM) for manual CC, 107 (105-127) CPM for CPRMeter, and 102 (101-102) CPM for LifeLine ARM (p = 0.027). The percentage of correct chest recoil was the highest for LifeLine ARM - 100% (95-100), 80% (60-90) in CPRMeter group, and the lowest for manual CC - 29% (26-48).
CONCLUSIONS: According to the results of this simulation trial, automated chest compression devices (ACCD) should be used for chest compression of patients with suspected/confirmed COVID-19. In the absence of ACCD, it seems reasonable to change the cardiopulmonary resuscitation algorithm (in the context of patients with suspected/confirmed COVID-19) by reducing the duration of the CPR cycle from the current 2-min to 1-min cycles due to a statistically significant reduction in the quality of chest compressions among rescuers wearing PPE AGP.

PMID: 32419128 [PubMed - as supplied by publisher]