Safety of performing transoesophageal echocardiography in patients with oesophageal varices.

Heart Asia. 2019;11(2):e011223

Authors: Hudhud D, Allaham H, Eniezat M, Enezate T

Abstract
Introduction: Oesophageal varices (EV) are one of the complications of liver cirrhosis that carries a risk of rupture and bleeding. The safety of performing transesophageal echocardiography (TEE) in patients with pre-existing EV is not well described in literature. Therefore, this retrospective study has been conducted to evaluate the safety of preforming TEE in this group of patients.
Methods: The study population was extracted from the 2016 Nationwide Readmissions Data using International Classification of Diseases, Tenth Revision, Clinical Modification/Procedure Coding System for EV, TEE and in-hospital outcomes. Study endpoints included in-hospital all-cause mortality, hospital length of stay, postprocedural gastrointestinal bleeding and oesophageal perforation.
Results: A total of 81 328 discharges with a diagnosis of EV were identified, among which 242 had a TEE performed during the index hospitalisation. Mean age was 58.3 years, 36.6% female. In comparison to the no-TEE group, the TEE group was associated with comparable in-hospital all-cause mortality (7.0% vs 6.7%, p=0.86) and bleeding (0.9% vs 1.1%, p=0.75); however, TEE group was associated with longer hospital stay (14.9 days vs 6.9 days, p<0.01). There were no reported oesophageal perforations.
Conclusions: TEE is not a common procedure performed in patients with pre-existing EV. TEE seems to be a safe diagnostic tool for evaluation of heart diseases in this group of patients.