Clin Radiol. 2019 May 23;:

Authors: Hynes JP, Murray AS, Murray OM, Eustace SK, Gilchrist S, Dolan A, Lawler LP

Abstract
AIM: The aim of this study was to assess the use of Lean Six Sigma methodology to improve the turnaround time (TAT) for inpatient peripherally inserted central catheter (PICC) placement.
MATERIALS AND METHODS: Value stream mapping was used to analyse the workflow process for inpatient PICC placement and to divide it into its component parts. Unnecessary steps were eliminated and variation minimised in the remaining processes. The TAT for PICC line placement was recorded for the 6 months prior to implementation of changes, and subsequently, at the 6-month and 2-year follow-up points.
RESULTS: Prior to implementing the changes, the mean TAT for PICC line placement was 3.74±3.28 days (95% confidence interval [CI]=3.3-4.17). Six months after implementation, the mean TAT was 1.89±1.82 days (95% CI=1.72-2.06, p<0.0001). The reduction was sustained such that at 2 years post-implementation the mean TAT was 1.88±1.87 days (95% CI=1.78-1.99, p<0.0001). This was achieved despite a 13.8% increase in overall interventional radiological activity.
CONCLUSION: By applying Lean Six Sigma methodology to the complex multifactorial processes involved from ordering a PICC to its final insertion, it was possible to identify areas for improvement and to introduce simple, effective measures that resulted in a significant sustained decrease in the TAT without additional resources.

PMID: 31128853 [PubMed - as supplied by publisher]