Clinical outcomes in patients with ST-segment elevation myocardial infarction treated with everolimus-eluting stents versus bare-metal stents (EXAMINATION): 5-year results of a randomised trial.

Link to article at PubMed

Related Articles

Clinical outcomes in patients with ST-segment elevation myocardial infarction treated with everolimus-eluting stents versus bare-metal stents (EXAMINATION): 5-year results of a randomised trial.

Lancet. 2015 Oct 28;

Authors: Sabaté M, Brugaletta S, Cequier A, Iñiguez A, Serra A, Jiménez-Quevedo P, Mainar V, Campo G, Tespili M, den Heijer P, Bethencourt A, Vazquez N, van Es GA, Backx B, Valgimigli M, Serruys PW

Abstract
BACKGROUND: Data for the safety and efficacy of new-generation drug-eluting stents at long-term follow-up, and specifically in patients with ST-segment elevation myocardial infarction, are scarce. In the EXAMINATION trial, we compared everolimus-eluting stents (EES) with bare-metal stents (BMS) in an all-comer population with ST-segment elevation myocardial infarction. In this study, we assessed the 5-year outcomes of the population in the EXAMINATION trial.
METHODS: In the multicentre EXAMINATION trial, done in Italy, Spain, and the Netherlands, patients with ST-segment elevation myocardial infarction were randomly assigned in a 1:1 ratio to receive EES or BMS. The random allocation schedule was computer-generated and central randomisation (by telephone) was used to allocate patients in blocks of four or six, stratified by centre. Patients were masked to treatment assignment. At 5 years, we assessed the combined patient-oriented outcome of all-cause death, any myocardial infarction, or any revascularisation. Analysis was by intention to treat. This trial is registered with ClinicalTrials.gov, number NCT00828087.
FINDINGS: 1498 patients were randomly assigned to receive either EES (n=751) or BMS (n=747). At 5 years, complete clinical follow-up data were obtained for 731 patients treated with EES and 727 treated with BMS (97% of both groups). The patient-oriented endpoint occurred in 159 (21%) patients in the EES group versus 192 (26%) in the BMS group (hazard ratio 0·80, 95% CI 0·65-0·98; p=0·033). This difference was mainly driven by a reduced rate of all-cause mortality (65 [9%] vs 88 [12%]; 0·72, 0·52-0·10; p=0·047).
INTERPRETATION: Our findings should be taken as a point of reference for the assessment of new bioresorbable polymer-based metallic stents or bioresorbable scaffolds in patients with ST-segment elevation myocardial infarction.
FUNDING: Spanish Heart Foundation.

PMID: 26520230 [PubMed - as supplied by publisher]

Leave a Reply

Your email address will not be published. Required fields are marked *