Comparison of conventional and high-sensitivity troponin in patients with chest pain: A collaborative meta-analysis.

Link to article at PubMed

Comparison of conventional and high-sensitivity troponin in patients with chest pain: A collaborative meta-analysis.

Am Heart J. 2015 Jan;169(1):6-16.e6

Authors: Lipinski MJ, Baker NC, Escárcega RO, Torguson R, Chen F, Aldous SJ, Christ M, Collinson PO, Goodacre SW, Mair J, Inoue K, Lotze U, Sebbane M, Cristol JP, Freund Y, Chenevier-Gobeaux C, Meune C, Eggers KM, Pracoń R, Schreiber DH, Wu AH, Ordoñez-Llanos J, Jaffe AS, Twerenbold R, Mueller C, Waksman R

Abstract
BACKGROUND: Multiple studies have evaluated the diagnostic and prognostic performance of conventional troponin (cTn) and high-sensitivity troponin (hs-cTn). We performed a collaborative meta-analysis comparing cTn and hs-cTn for diagnosis of acute myocardial infarction (AMI) and assessment of prognosis in patients with chest pain.
METHODS: MEDLINE/PubMed, Cochrane CENTRAL, and EMBASE were searched for studies assessing both cTn and hs-cTn in patients with chest pain. Study authors were contacted and many provided previously unpublished data.
RESULTS: From 17 included studies, there were 8,644 patients. Compared with baseline cTn, baseline hs-cTn had significantly greater sensitivity (0.884 vs 0.749, P < .001) and negative predictive value (NPV; 0.964 vs 0.935, P < .001), whereas specificity (0.816 vs 0.938, P < .001) and positive predictive value (0.558 vs 0.759, P < .001) were significantly reduced. Based on summary receiver operating characteristic curves, test performance for the diagnosis of AMI was not significantly different between baseline cTn and hs-cTn (0.90 [95% CI 0.85-0.95] vs 0.92 [95% CI 0.90-0.94]). In a subanalysis of 6 studies that alternatively defined AMI based on hs-cTn, cTn had lower sensitivity (0.666, P < .001) and NPV (0.906, P < .001). Elevation of baseline hs-cTn, but negative baseline cTn, was associated with increased risk of death or nonfatal myocardial infarction during follow-up (P < .001) compared with both negative.
CONCLUSION: High-sensitivity troponin has significantly greater early sensitivity and NPV for the diagnosis of AMI at the cost of specificity and positive predictive value, which may enable early rule in/out of AMI in patients with chest pain. Baseline hs-cTn elevation in the setting of negative cTn is also associated with increased nonfatal myocardial infarction or death during follow-up.

PMID: 25497242 [PubMed - as supplied by publisher]