Accuracy of a radiofrequency identification (RFID) badge system to monitor hand hygiene behavior during routine clinical activities.

Link to article at PubMed

Related Articles

Accuracy of a radiofrequency identification (RFID) badge system to monitor hand hygiene behavior during routine clinical activities.

Am J Infect Control. 2013 Dec 17;

Authors: Pineles LL, Morgan DJ, Limper HM, Weber SG, Thom KA, Perencevich EN, Harris AD, Landon E

Abstract
BACKGROUND: Hand hygiene (HH) is a critical part of infection prevention in health care settings. Hospitals around the world continuously struggle to improve health care personnel (HCP) HH compliance. The current gold standard for monitoring compliance is direct observation; however, this method is time-consuming and costly. One emerging area of interest involves automated systems for monitoring HH behavior such as radiofrequency identification (RFID) tracking systems.
METHODS: To assess the accuracy of a commercially available RFID system in detecting HCP HH behavior, we compared direct observation with data collected by the RFID system in a simulated validation setting and to a real-life clinical setting over 2 hospitals.
RESULTS: A total of 1,554 HH events was observed. Accuracy for identifying HH events was high in the simulated validation setting (88.5%) but relatively low in the real-life clinical setting (52.4%). This difference was significant (P < .01). Accuracy for detecting HCP movement into and out of patient rooms was also high in the simulated setting but not in the real-life clinical setting (100% on entry and exit in simulated setting vs 54.3% entry and 49.5% exit in real-life clinical setting, P < .01).
CONCLUSION: In this validation study of an RFID system, almost half of the HH events were missed. More research is necessary to further develop these systems and improve accuracy prior to widespread adoption.

PMID: 24355492 [PubMed - as supplied by publisher]