Copeptin Improves the Diagnostic Performance of Sensitive Troponin I-Ultra but Cannot Rapidly Rule Out Non-ST-Elevation Myocardial Infarction at Presentation to an Emergency Department.

Link to article at PubMed

Copeptin Improves the Diagnostic Performance of Sensitive Troponin I-Ultra but Cannot Rapidly Rule Out Non-ST-Elevation Myocardial Infarction at Presentation to an Emergency Department.

Ann Emerg Med. 2013 Mar 2;

Authors: Charpentier S, Lepage B, Maupas-Schwalm F, Cinq-Frais C, Bichard-Bréaud M, Botella JM, Elbaz M, Lauque D

Abstract

STUDY OBJECTIVE: We assess the performance of a single multimarker strategy, using a combination of sensitive troponin I-Ultra and copeptin assays to rule out non-ST-elevation myocardial infarction (NSTEMI) at presentation to an emergency department (ED). METHODS: A secondary analysis was carried out on 587 consecutive patients with chest pain who presented to the ED without ST elevation on ECG and were included in a single-site, prospective observational study. Samples for copeptin and combination of sensitive troponin I-Ultra assays were collected at presentation. The performance of the combination of copeptin and combination of sensitive troponin I-Ultra for NSTEMI was calculated in the whole cohort and after stratification by thrombosis in myocardial infarction (TIMI) risk score. RESULTS: NSTEMI was diagnosed in 87 patients (14.8%). The sensitivity and the negative predictive value of the combination of copeptin and combination of sensitive troponin I-Ultra were 96.6% (95% confidence interval [CI] 90.3% to 99.3%) and 99.1% (95% CI 97.4% to 99.8%), respectively, for a cutoff level of copeptin less than 12 pmol/L. Among the 243 patients with a low TIMI score, all 8 who had an NSTEMI were detected with the combination (sensitivity 100%; 95% CI 63.1% to 100%), and 158 were a combination of sensitive troponin I-Ultra and copeptin negative and had no NSTEMI (negative predictive value 100%; 95% CI 97.7% to 100%). CONCLUSION: In this study, the combination of sensitive troponin and copeptin measurements had a high sensitivity and negative predictive value for NSTEMI diagnosis, especially among subjects with a low TIMI risk score. However, the sensitivity was too low to rule out NSTEMI with a single-draw strategy at ED presentation. Future studies are needed on the low-risk TIMI group to further investigate this preliminary finding.

PMID: 23465302 [PubMed - as supplied by publisher]

Leave a Reply

Your email address will not be published. Required fields are marked *