Computerized intensive insulin dosing can mitigate hypoglycemia and achieve tight glycemic control when glucose measurement is performed frequently and on time.

Link to article at PubMed

Related Articles

Computerized intensive insulin dosing can mitigate hypoglycemia and achieve tight glycemic control when glucose measurement is performed frequently and on time.

Crit Care. 2009 Oct 12;13(5):R163

Authors: Juneja R, Roudebush CP, Nasraway SA, Golas AA, Jacobi J, Carroll J, Nelson D, Abad VJ, Flanders SJ

ABSTRACT: INTRODUCTION: Control of blood glucose (BG) in critically ill patients is considered important, but is difficult to achieve, and often associated with increased risk of hypoglycemia. We examined the use of a computerized insulin dosing algorithm to manage hyperglycemia with particular attention to frequency and conditions surrounding hypoglycemic events. METHODS: This is a retrospective analysis of adult patients with hyperglycemia receiving intravenous (IV) insulin therapy from March 2006 to December 2007 in the intensive care units of 2 tertiary care teaching hospitals. Patients placed on a glycemic control protocol using the Clarian GlucoStabilizerTM IV insulin dosing calculator with a target range of 4.4-6.1 mmol/L were analyzed. Metrics included time to target, time in target, mean blood glucose +/- standard deviation, % measures in hypoglycemic ranges <3.9 mmol/L, per-patient hypoglycemia, and blood glucose level testing interval. RESULTS: 4,588 ICU patients were treated with the GlucoStabilizer to a BG target range of 4.4-6.1 mmol/L. We observed 254 severe hypoglycemia episodes (BG <2.2 mmol/L) in 195 patients, representing 0.1% of all measurements, and in 4.25% of patients or 0.6 episodes per 1000 hours on insulin infusion. The most common contributing cause for hypoglycemia was measurement delay (n=170, 66.9%). The median (interquartile range) time to achieve the target range was 5.9 (3.8 - 8.9) hours. Nearly all (97.5%) of patients achieved target and remained in target 73.4% of the time. The mean BG (+/- SD) after achieving target was 5.4 (+/- .52) mmol/L. Targeted blood glucose levels were achieved at similar rates with low incidence of severe hypoglycemia in patients with and without diabetes, sepsis, renal, and cardiovascular disease. CONCLUSIONS: Glycemic control to a lower glucose target range can be achieved using a computerized insulin dosing protocol. With particular attention to timely measurement and adjustment of insulin doses, the risk of hypoglycemia experienced can be minimized.

PMID: 19822000 [PubMed - as supplied by publisher]

Leave a Reply

Your email address will not be published. Required fields are marked *